Effective beam directions using radiobiologically optimized IMRT of node positive breast cancer

  • Brigida Costa Ferreira

      Affiliations

    • Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm (Sweden)
    • Corresponding Author InformationAddress for correspondence: B. Costa Ferreira, Department of Medical Radiation Physics, Karolinska Institutet, PO Box 260, S-171 76 Stockholm, Sweden. Tel: +468 517 72776; Fax: +468 343525
  • ,
  • Roger Svensson

      Affiliations

    • Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm (Sweden)
  • ,
  • Bengt Lind

      Affiliations

    • Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm (Sweden)
  • ,
  • Jonas Johansson

      Affiliations

    • Section of Oncology, University of Uppsala, Akademiska sjukhuset, Uppsala (Sweden)
  • ,
  • Anders Brahme

      Affiliations

    • Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm (Sweden)

Received 7 October 2005; received in revised form 29 March 2006; accepted 4 April 2006.

Abstract 

The purpose of this study was to investigate the optimal coplanar beam directions when treating an early breast cancer with locoregional lymphatic spread with a few radiobiologically optimized intensity modulated beams. Also to determine the increase in the probability of complication-free cure with the number of beam portals and the smallest number required to perform a close to optimal treatment for this tumour site.

Four test patients with stage II left-sided breast cancer were studied with heart, lung and contralateral breast as principal organs at risk. The clinical target volume consisted of the breast tissue remaining after surgery, the axillary, the internal mammary as well as the supraclavicular lymph nodes. Through an exhaustive search of all possible beam directions the most effective coplanar beams with one to four intensity modulated photon beam portals were investigated. Comparisons with uniform beam treatment techniques and up to 12 intensity modulated beams were also made. The different plans were optimized using the probability of complication-free tumour cure, P+, as biological objective function.

When using two intensity modulated beam directions three major sets of suitable directions were identified denoted by A, P and T. A corresponds to an anterior oblique pair of beams around 25° and 325°, P is a perpendicular lateral pair at around 50° and 130° whereas T is a more conventional tangential pair at around 155° and 300°. Interestingly, these configurations identify simply three major effective beam directions namely at 30°±20°, 145°±20° and 310°±15°. For the three intensity modulated beam technique a combination of these three effective beam directions generally covered the global maximum of the probability of complication-free tumour control.

The improvement in complication-free cure probability with two optimally selected intensity modulated beams is around 10% when compared to a uniform beam technique with three to four beam portals. This increase is mainly due to a reduction by almost 1% in the probability of injury to the heart and an increase of 6% in the probability of local tumour control. When three or four biologically optimized beam portals are used a further increase in the probability of complication-free cure of about 6% can often be obtained. This improvement is caused by a small decrease in the probability of injury to the heart, left lung and other surrounding normal tissue, as well as a slight further increase in the probability of tumour control. The increase in the treatment outcome is minimal when more than four intensity modulated beams are employed. A small increase in dose homogeneity in the target volume and a slight decrease in the normal tissue volume receiving high dose may be seen, but without appreciably improving the complication-free cure probability.

For a stage II breast cancer, three and in more complex cases four optimally oriented beams are sufficient to reach close to the maximum probability of complication-free tumour control when biologically optimized intensity modulated dose delivery is used. Angle of incidence optimization may then be advantageous starting from the given most effective three beam directions.

Breast cancer, intensity modulation, biological treatment optimization, angle of incidence optimization

No full text is available. To read the body of this article, please view the PDF online.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1120-1797(06)80005-0

doi:10.1016/S1120-1797(06)80005-0

Physica Medica: European Journal of Medical Physics
Volume 22, Issue 1 , Pages 3-15, January 2006