« Previous
Next »
Physica Medica: European Journal of Medical Physics
Volume 23, Issue 2
, Pages 58-66
, June 2007
A new method for output factor determination in MLC shaped narrow beams
References
- Absorbed dose determination in external beam radiotherapy: an International Code of Practice for dosimetry based on standards of absorbed dose to water. IAEA technical report series no. 398. Vienna: International Atomic Energy Agency; 2000;
- AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys. 1999;26:1847–1870
- Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams. Phys Med Biol. 2003;48:2081–2099
- . A comparison of dosimetry techniques in stereotactic radiosurgery. Phys Med Biol. 1996;41:93–110
- . Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams. Med Phys. 1998;25:503–511
- . Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition. Phys Med Biol. 1999;44:2143–2160
- . Comparative dosimetry in narrow high-energy photon beams. Phys Med Biol. 2000;45:685–702
- . Physical aspects of dynamic stereotactic radiosurgery with very small photon beams (1.5 and 3 mm in diameter). Med Phys. 2003;30:111–118
- . The volume effect of detectors in the dosimetry of small fields used in IMRT. Med Phys. 2003;30:341–347
- . Investigation of photon beam output factors for conformal radiation therapy—Monte Carlo simulations and measurements. Phys Med Biol. 2002;47:N133–N143
- . Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams. Med Phys. 1999;26:1874–1882
- . An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets. Med Phys. 2004;31:2416–2422
- Micro ionization chamber dosimetry in IMRT verification: clinical implications of dosimetric errors in the PTV. Radiother Oncol. 2005;75:342–348
- Microionization chamber for reference dosimetry in IMRT verification: clinical implications on OAR dosimetric errors. Phys Med Biol. 2005;50:959–970
- . Monte Carlo correction factors for a Farmer 0.6 cm3 ion chamber dose measurement in the build up of the 6 MV clinical beam. Phys Med Biol. 2006;51:1523–1532
- . The dose-area product, a new parameter for the dosimetry of narrow photon beams. Z Med Phys. 2006;16(3):217–227
- . Automatic determination of primary electron beam parameters in Monte Carlo simulation. Med Phys. 2007;34(3):1076–1084
- . BEAM: a Monte Carlo code to simulate radiotherapy treatment units. Med Phys. 1995;22:503–524
- . NRC User codes for EGSnrc. Technical report PIRS-702 revB. Ottawa: National Research Council of Canada; 2005;
PII: S1120-1797(07)00009-9
doi: 10.1016/j.ejmp.2007.03.002
« Previous
Next »
Physica Medica: European Journal of Medical Physics
Volume 23, Issue 2
, Pages 58-66
, June 2007
