Physica Medica: European Journal of Medical Physics
Volume 25, Issue 1 , Pages 47-50, March 2009

A new specially designed needle significantly increases sample yield during fine needle aspiration of breast lesions

  • H. Wiksell

      Affiliations

    • Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
  • ,
  • V. Ekstrand

      Affiliations

    • Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
    • Corresponding Author InformationCorresponding author. Box 39011, 100 54 Stockholm, Sweden.
  • ,
  • C. Wadström

      Affiliations

    • Stockholm Breast Clinic, Sweden
  • ,
  • G. Auer

      Affiliations

    • Stockholm Breast Clinic, Sweden
    • Karolinska Biomic Center, Karolinska Institutet, Stockholm, Sweden

Received 20 November 2007; received in revised form 15 January 2008; accepted 15 January 2008. published online 04 March 2008.

Abstract 

A large and increasing number of women in the western world will at some point during their life be investigated morphologically for breast cancer. Fine needle aspiration (FNA) is one morphological method which is considered to be the fastest, cheapest and the most patient-friendly approach. Nevertheless, the technique has not gained major clinical success outside of Scandinavia, mainly because of a high frequency of insufficient samples. With this in mind it is quite peculiar that standard needles which are mainly configured for blood sampling and infusion therapy, comprising large quantities of residual spaces, are used. In this study we have developed and tested a new needle dedicated for FNA, which is intended to abate this drawback by increasing the sampling yield by changing the tip angle, the cannula wall-thickness and the storage compartment. In total, 499 consecutive aspiration procedures of palpable breast lesions were performed to compare the new needle (outer diameter 0.6mm) with standard needles (outer diameters 0.6mm and 0.7mm). The new needle provided three times more material than did standard needles of the same diameter. Surprisingly, the new needle also provided more material than the standard 0.7mm needle, which increased up to almost twice the material in cases with no material in the syringe. The frequency of tests with sparse harvested material (<4mg) was less with the new needle (9%) compared to its standard counterpart (35%). The presented results were obtained by a very skilled sampling operator. Thus for the average sampling operator who probably obtains more samples in the spare range, the new dedicated FNA needle should have even more added value.

Keywords: Breast, FNA, Biopsy, Aspiration

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1120-1797(08)00028-8

doi:10.1016/j.ejmp.2008.01.009

Physica Medica: European Journal of Medical Physics
Volume 25, Issue 1 , Pages 47-50, March 2009