Physica Medica: European Journal of Medical Physics
Volume 25, Issue 2 , Pages 51-57 , June 2009

Benchmark of penelope for low and medium energy X-rays

  • U. Chica

      Affiliations

    • Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada, Spain
    • Unidad de Radiología, Facultad de Odontología, Universidad Nacional de Colombia, Bogotá D.C., Colombia
  • ,
  • M. Anguiano

      Affiliations

    • Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada, Spain
  • ,
  • A.M. Lallena

      Affiliations

    • Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada, Spain
    • Corresponding Author InformationCorresponding author. Tel.: +34 958 243216.

Received 25 January 2008 ,Revised 7 April 2008 ,Accepted 8 April 2008.

References 

  1. Blattmann H, Gebbers JO, Brauer-Krisch E, Bravin A, Le Duc G, Burkard W, et al. Applications of synchrotron X-rays to radiotherapy. Nucl Instrum Methods Phys Res A. 2005;548:17–22
  2. Murphy MJ, Balter J, Balter S, BenComo JA, Das IJ, Jiang SB, et al. The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. Med Phys. 2007;34:4041–4063
  3. Verellen D, Ridder MD, Storme G. A (short) history of image-guided radiotherapy. Radiother Oncol. 2008;86:4–13
  4. Verhaegen F, Reniers B, Deblois F, Devic S, Seuntjens J, Hristov D. Dosimetric and microdosimetric study of contrast-enhanced radiotherapy with kilovolt x-rays. Phys Med Biol. 2005;50:3555–3569
  5. Salvat F, Fernández-Varea JM, Sempau J. PENELOPE – a code system for Monte Carlo simulation of electron and photon transport. Paris: Nuclear Energy Agency; 2006;
  6. Ye S, Brezovich I, Pareek P, Naqvi S. Benchmark of PENELOPE code for low-energy photon transport: dose comparisons with MCNP4 and EGS4. Phys Med Biol. 2004;49:387–397
  7. Almansa JF, Guerrero R, Al-Dweri F, Anguiano M, Lallena AM. Dose distribution in water for monoenergetic photon point sources in the energy range of interest in brachytherapy: Monte Carlo simulations with PENELOPE and GEANT4. Radiat Phys Chem. 2007;76:766–773
  8. Nowotny R, Höfer A. Ein Programm für die Berechnung von Diagnostischen Röntgenspektren. Fortschr Röntgenstr. 1985;142:685–689
  9. Ankerhold U. Catalogue of x-ray spectra and their characteristic data: ISO and DIN radiation qualities, therapy and diagnostic radiation qualities, unfiltered x-ray spectra. PTB-Dos-34 PTB report. Bremerhaven: Wirtschaftsverlag N.W; 2000;
  10. Matzke M. Unfolding of pulse height spectra: the HEPRO program system. Bremerhaven: Wirtschaftsverlag N.W; 1994;
  11. Ma C-M, Coffey CW, DeWerd LA, Liu C, Nath R, Seltzer SM, et al. AAPM protocol for 40–300.kV x-ray beam dosimetry in radiotherapy and radiobiology. Med Phys. 2001;28:868–893
  12. International Atomic Energy Agency . Absorbed dose determination in external beam radiotherapy. IAEA technical report series 398. Vienna: IAEA; 2005;
  13. International Organization for Standardization . Guide to the expression of uncertainty in measurement. 2nd ed.. Geneva: ISO; 1995;
  14. Berger MJ. Monte Carlo calculation of the penetration and diffusion of fast charged particles. In:  Alder B,  Fernbach S,  Rotenberg M editor. Methods in computational physics. vol. 1:New York: Academic Press; 1963;
  15. Birch R, Marshall M. Computation of Bremsstrahlung x-ray spectra and comparison with spectra measured with a Ge(Li) detector. Phys Med Biol. 1979;24:505–517
  16. Tucker DM, Barnes GT, Chakraborty DP. Semiempirical model for generating tungsten target x-ray spectra. Med Phys. 1991;18:211–218
  17. Ay M, Sarkar S, Shahriani M, Sardiri D, Zaidi H. Nuclear science symposium conference record 2004 IEEE, Comparative assessment of different computational models for generation of x-ray spectra in diagnostic radiology and mammography. 2004;7:4190–4194
  18. Meyer P, Buffard E, Mertz L, Kennel C, Constantinesco A, Siffert P. Evaluation of the use of six diagnostic x-ray spectra computer codes. Br J Radiol. 2004;77:224–230
  19. ISO . X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy: part 1. Radiation characteristics and production methods ISO 4037-1. Geneva: International Organization for Standardization; 1996;
  20. Rosser KE. An alternative beam quality index for medium-energy x-ray dosimetry. Phys Med Biol. 1998;43:587–598

PII: S1120-1797(08)00048-3

doi: 10.1016/j.ejmp.2008.04.001

Physica Medica: European Journal of Medical Physics
Volume 25, Issue 2 , Pages 51-57 , June 2009