« Previous
Next »
Physica Medica: European Journal of Medical Physics
Volume 26, Issue 1
, Pages 44-48
, January 2010
Spatial distribution of beta extremity doses in nuclear medicine: A feasibility study with thin α-Al2O3:C TLDs
References
- Dhanse S, Martin CJ, Hilditch TE, Elliot AT. A study of doses to hands during dispensing of radiopharmaceuticals. Nucl Med Commun 200;21:511–519.
- An overview on extremity dosimetry in medical applications. Radiat Prot Dosimetry. 2008;129:350–355
- Extremity ring dosimetry intercomparison in reference and workplace fields. Radiat Prot Dosimetry. 2008;131:67–72
- An overview of the use of extremity dosemeters in some European countries for medical application. Radiat Prot Dosimetry. 2008;131:62–66
- . Recommendations of the international commission on radiological protection. ICRP Publication 60 Ann ICRP. 1991;21:
- Council Directive 96/29/EURATOM of 13 May 1996 laying down basic safety standards for the protection of the health of workers and the general public against the dangers arising from ionizing radiations. Off J Eur Commun. 1996;39L:159
- . Application of ALARP to extremity doses for hospital workers. J Radiol Prot. 2003;23:405–421
- Aubert B, Guilabert N, Lamon A, Ricard M. Which protection against radiation for new protocols of internal radiotherapy by yttrium 90? In: Proceeding of the sixth European ALARA network workshop ‘occupation exposure optimisation in the medical field and radiopharmaceutical industry’, Madrid, 23–25 October 2002. p. 47–9.
- Barth I, Mielcarek J. Occupation radiation exposure during radiosynoviorthesis. In: Proceeding of the sixth European ALARA network workshop ‘occupation exposure optimisation in the medical field and radiopharmaceutical industry’, Madrid, 23–25 October 2002. p. 43–6.
- Radiation protection in radionuclide therapies with 90Y-conjugates: risks and safety. Eur J Nucl Med Mol Imaging. 2006;33:1321–1327
- Radiation exposure in 90Y-Zevalin therapy. Nuklearmedizin. 2006;45:82–86
- . Beta radiation exposure of medical staff and implications for extremity dose monitoring. Radiat Prot Dosimetry. 2007;125:335–339
- . Beta radiation exposure of staff during and after therapies with 90Y-labelled substances. Radiat Prot Dosimetry. 2008;131:73–79
- . Highly sensitive anion defective α-Al2O3:C single crystal detectors. Radiat Prot Dosimetry. 1990;32:15–20
- . A thin layer α-Al2O3:C beta TL detector. Radiat Prot Dosimetry. 1996;66:105–110
- . Angular dependence of the TL reading of thin α-Al2O3:C dosimeters exposed to different beta spectra. Radiat Prot Dosimetry. 2005;113:359–365
- Birattari C. Studio per l'ottimizzazione della terapia metabolica con radiofarmaci per la palliazione del dolore osseo. Relazione finale progetto Ratermet – Programma speciale della Regione Lombardia 2002–2004. Raccolta Convenzioni e Contratti n. 5244/RCC del 28.03.03 [in Italian].
- . Uncertainly analysis of absorbed dose calculations from thermoluminescence dosimeters. Med Phys. 1992;19:1427–1433
- . Hand exposure to ionising radiation of nuclear medicine workers. Radiat Prot Dosimetry. 2008;130:325–330
PII: S1120-1797(09)00015-5
doi: 10.1016/j.ejmp.2009.02.004
© 2009 Associazione Italiana di Fisica Medica. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Physica Medica: European Journal of Medical Physics
Volume 26, Issue 1
, Pages 44-48
, January 2010