« Previous
Next »
Physica Medica: European Journal of Medical Physics
Volume 26, Issue 1
, Pages 38-43
, January 2010
Evaluation criteria for film based intensity modulated radiation therapy quality assurance
References
- Intensity-modulated radiation therapy reduces late salivary toxicity without compromising tumor control in patients with oropharyngeal carcinoma: a comparison with conventional techniques. Radiother Oncol. 2001;61:275–280
- Matched case-control study of quality of life and xerostomia after intensity-modulated radiotherapy or standard radiotherapy for head and neck cancer: initial report. Int J Radiat Oncol Biol Phys. 2005;63:725–731
- Intensity-modulated radiotherapy in the treatment of nasopharyngeal carcinoma: an update of the UCSF experience. Int J Radiat Oncol Biol Phys. 2002;53:12–22
- . Tumor response and salivary function sparing in patients with oropharyngeal squamous cell carcinoma treated with intensity modulated radiation therapy (IMRT) with/without chemotherapy: the Mallinckrodt Institute of Radiology initial results. Int J Radiat Oncol Biol Phys. 2000;48:175–176
- . Intensity-modulated radiation therapy (IMRT) reduces small bowel, rectum, and bladder doses in patients with cervical cancer receiving pelvic and para-aortic irradiation. Int J Radiat Oncol Biol Phys. 2001;51:261–266
- Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate. Int J Radiat Oncol Biol Phys. 1997;39:863–873
- . A comparison of three stereotactic radiotherapy techniques; ARCS vs. noncoplanar fixed field vs. intensity modulation. Int J Radiat Oncol Biol Phys. 1998;42:431–436
- . Static field intensity modulation to treat a dominant intra-prostatic lesion to 90
Gy compared to seven field 3-dimensional radiotherapy. Int J Radiat Oncol Biol Phys. 1999;44:921–929 - A feasibility study of automated inverse treatment planning for cancer of the prostate. Int J Radiat Oncol Biol Phys. 1998;40:207–214
- . Comparison of three-dimensional conformal radiation therapy and intensity-modulated radiation therapy systems. Semin Oncol. 1999;9:78–98
- . Intensity-modulated radiotherapy: current status and issues of interest. Int J Radiat Oncol Biol Phys. 2001;51:880–914
- . Clinical use of EBT model Gafchromic™ film in radiotherapy. Med Phys. 2006;33:4314–4319
- . Commissioning and quality assurance of treatment planning computers. Int J Radiat Oncol Biol Phys. 1993;26:261–273
- . A technique for the quantitative evaluation of dose distributions. Med Phys. 1998;25:656–661
- . Geometric interpretation of the dose distribution comparison technique: interpolation free calculation. Med Phys. 2008;35:879–887
- . On dose distribution comparison. Phys Med Biol. 2006;51:759–776
- . Evaluation of the gamma dose distribution comparison method. Med Phys. 2003;30:2455–2464
- . Gamma histograms for radiotherapy plan evaluation. Radiother Oncol. 2006;79:224–230
- AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys. 1999;26:1847–1870
- Precise radiochromic film dosimetry using a flat-bed document scanner. Med Phys. 2005;32:2245–2253
- . The use of an inexpensive red acetate filter to improve the sensitivity of Gafchromic dosimetry. Med Phys. 2001;28:1446–1448
- . Absorption spectra variations of EBT radiochromic film from radiation exposure. Phys Med Biol. 2005;50:135–140
- . A study of Gafchromic XR Type R film response with reflective-type densitometers and economical flatbed scanners. J Appl Clin Med Phys. 2003;4:307–314
- . Dosimetric verification of intensity modulated radiation therapy of 172 patients treated for various disease sites: comparison of EBT film dosimetry, ion chamber measurements, and independent MU calculations. Med Dosim. 2008;33:303–309
- Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT subcommittee of the AAPM radiation therapy committee. Med Phys. 2003;30:2089–2115
- . An analysis of tolerance levels in IMRT quality assurance procedures. Med Phys. 2008;35:2300–2307
- . Tolerance limits and action levels for planning and delivery of IMRT. Intensity modulated radiation therapy: the state of the art. Wisconsin: Medical Physics Publishing; 2003;pp. 593–612
- . Quality assurance of intensity-modulated radiation therapy. Int J Radiat Oncol Biol Phys. 2008;71:S108–S112
- . Dose verification in clinical IMRT prostate incidents. Int J Radiat Oncol Biol Phys. 2004;59:1540–1547
- Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification. Med Dosim. 2006;31:273–282
- . IMRT head and neck phantom irradiations: correlation of results with institution size. Med Phys. 2005;32:1983–1984
- . Accurate dosimetry with Gafchromic™ EBT film of a 6 MV photon beam in water: what level is achievable?. Med Phys. 2008;35:704–716
- . Sensitivity of linear CCD array based film scanners used for film dosimetry. Med Phys. 2006;33:3993–3996
- . American association of physicists in medicine radiation therapy committee task group 53: quality assurance for clinical radiotherapy treatment planning. Med Phys. 1998;25:1773–1829
PII: S1120-1797(09)00035-0
doi: 10.1016/j.ejmp.2009.06.002
© 2009 Associazione Italiana di Fisica Medica. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Physica Medica: European Journal of Medical Physics
Volume 26, Issue 1
, Pages 38-43
, January 2010
