Registration of on-board X-ray images with 4DCT: A proposed method of phase and setup verification for gated radiotherapy

  • Qianyi Xu

      Affiliations

    • Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ 85721, USA
    • Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    • Corresponding Author InformationCorresponding author. Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ 85721, USA.
  • ,
  • Zhijun He

      Affiliations

    • Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ 85721, USA
  • ,
  • Jiajin Fan

      Affiliations

    • Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
  • ,
  • Russell J. Hamilton

      Affiliations

    • Department of Radiation Oncology, University of Arizona, Tucson, AZ 85724, USA
  • ,
  • Yan Chen

      Affiliations

    • Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
  • ,
  • C.-M. Ma

      Affiliations

    • Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
  • ,
  • Lei Xing

      Affiliations

    • Department of Radiation Oncology, School of Medicine, Stanford University, Stanford, CA 94305, USA

Received 4 July 2007; received in revised form 15 July 2009; accepted 1 September 2009. published online 05 October 2009.

Abstract 

Current gated radiation therapy starts with simulation 4DCT images of a patient with lung cancer. We propose a method to confirm the phase of 4DCT for planning and setup position at the time of treatment. An intensity-based rigid algorithm was developed in this work to register an orthogonal set of on-board projection X-ray images with each phase of the 4DCT. Multiple DRRs for one of ten 4DCT phases are first generated and the correlation coefficient (CC) between the projection X-ray image and each DRR is computed. The maximum value of CC for the phase is found via a simulated annealing optimization process. The whole process repeats for all ten phases. The 4DCT phase that has the highest CC is identified as the breathing phase of the X-ray. The phase verification process is validated by a moving phantom study. Thus, the method may be used to independently confirm the correspondence between the gating phase at the times of 4DCT simulation and radiotherapy delivery. When the intended X-ray phase and actual gating phase are consistent, the registration of the DRRs and the projection images may also yield the values of patient shifts for treatment setup. This method could serve as the 4D analog of the conventional setup film as it provides both verification of the specific phase at the time of treatment and isocenter positioning shifts for treatment delivery.

Keywords: Setup verification, Registration, 4DCT

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1120-1797(09)00053-2

doi:10.1016/j.ejmp.2009.09.001

Physica Medica: European Journal of Medical Physics
Volume 26, Issue 3 , Pages 117-125, July 2010