Influence of Geant4 parameters on dose distribution and computation time for carbon ion therapy simulation

  • Nabil Zahra

      Affiliations

    • Université de Lyon, 69622 Lyon, France
    • IPNL-CNRS/IN2P3 UMR 5822, Université Lyon1, Villeurbanne, France
    • Centre de lutte contre le cancer Léon Berard, 28 rue Laennec, 69373 Lyon cedex 08, France
    • Corresponding Author InformationCorresponding author at: Centre de lutte contre le cancer Léon Bérard, service de Radiothérapie, 28 rue Laennec, 69 373 Lyon Cedex 08, France. Tel.: +33 4 78 78 51 51; fax: +33 4 78 78 59 98.
  • ,
  • Thibault Frisson

      Affiliations

    • Université de Lyon, 69622 Lyon, France
    • IPNL-CNRS/IN2P3 UMR 5822, Université Lyon1, Villeurbanne, France
    • Centre de lutte contre le cancer Léon Berard, 28 rue Laennec, 69373 Lyon cedex 08, France
    • Creatis LRMN-CNRS UMR 5220, INSERM U 630, INSA, Université Lyon 1, Villeurbanne, France
  • ,
  • Loic Grevillot

      Affiliations

    • Université de Lyon, 69622 Lyon, France
    • Centre de lutte contre le cancer Léon Berard, 28 rue Laennec, 69373 Lyon cedex 08, France
    • Creatis LRMN-CNRS UMR 5220, INSERM U 630, INSA, Université Lyon 1, Villeurbanne, France
    • IBA, Louvain-La-Neuve, Belgium
  • ,
  • Philippe Lautesse

      Affiliations

    • Université de Lyon, 69622 Lyon, France
    • IPNL-CNRS/IN2P3 UMR 5822, Université Lyon1, Villeurbanne, France
  • ,
  • David Sarrut

      Affiliations

    • Université de Lyon, 69622 Lyon, France
    • Centre de lutte contre le cancer Léon Berard, 28 rue Laennec, 69373 Lyon cedex 08, France
    • Creatis LRMN-CNRS UMR 5220, INSERM U 630, INSA, Université Lyon 1, Villeurbanne, France

Received 11 September 2009; received in revised form 17 November 2009; accepted 23 December 2009. published online 27 January 2010.

Abstract 

The aim of this work was to study the influence of Geant4 parameters on dose distribution and computational time for simulations of carbon ion therapy. The study was done using Geant4 version 9.0. The dose distribution in water for incident monoenergetic carbon ion beams of 300 MeV/u were compared for different values of secondary particle production threshold and different step limits. Variations of depth dose of about 2 mm were observed in some cases, which induced a 30% variation of dose deposit in the Bragg peak region. Other tests were done using Geant4 version 9.2 to verify the results from this study. The two versions provided converging results and led to the same conclusions.

Keywords: GEANT4, Dosimetry, Hadrontherapy, Linear energy transfer

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1120-1797(10)00002-5

doi:10.1016/j.ejmp.2009.12.001

Physica Medica: European Journal of Medical Physics
Volume 26, Issue 4 , Pages 202-208, October 2010