Physica Medica: European Journal of Medical Physics
Volume 26, Issue 4
, Pages 209-215
, October 2010
Reduction of patient dose in medical radiography by utilizing scattered X-rays: Relation between permissible limit of scatter fraction, viewer brightness, and perceptibility of vision
References
- . The effect of scatter reduction on the signal-to-noise ratio in computed radiography. Eur J Radiol. 1991;12:167–170
- . Grids or air gaps for scatter reduction in digital radiography: a model calculation. Med Phys. 1992;19:475–481
- . Scatter-reduction characteristics of an infinity-focused gridded radiographic cassette. Invest Radiol. 1994;29:852–855
- . Bayesian restoration of chest radiographs. Scatter compensation with improved signal-to-noise ratio. Invest Radiol. 1994;29:904–910
- . Scatter reduction in mammography with air gap. Med Phys. 1996;23:1263–1270
- . Improved Bayesian image estimation for digital chest radiography. Med Phys. 1997;24:539–545
- . Evaluating radiographic parameters for mobile chest computed radiography: phantoms, image quality and effective dose. Med Phys. 2003;30:2727–2735
- . Technical note: a comparison of antiscatter grids for digital radiography. Br J Radiol. 2004;77:950–952
- . Dose-image quality optimization in digital chest radiography. Radiat Prot Dosimetry. 2005;114:269–272
- . Experimental evaluation of fiber-interspaced antiscatter grids for large patient imaging with digital x-ray systems. Phys Med Biol. 2007;52:4863–4880
- . Assessment of the problem: pediatric doses in screen-film and digital radiography. Pediatr Radiol. 2004;34(Suppl. 3):S173–S182
- . Tradeoffs between image quality and dose. Pediatr Radiol. 2004;34(Suppl. 3):S183–S195
- . Phantom approach to find the optimal technical parameters for plain chest radiography. Br J Radiol. 2004;77:648–653
- Comparative scatter and dose performance of slot-scan and full-field digital chest radiography systems. Radiology. 2005;235:940–949
- . Scatter radiation in cephalometric radiography: the effects of grid and collimation. Dentomaxillofac Radiol. 2006;35:278–282
- . Effects of scattered-X-rays upon radiographic contrast and patient dose. J Photogr Sci. 1993;41:134–136
- . An example of the application of the contrast-dose diagram to medical radiographs. J Photogr Sci. 1995;43:95–98
- . The determination of the optimum density and the density-range of radiographs from visual effects. Jpn J Appl Phys. 1964;3:286–294
- . Determination of optimum film density range for roentgenograms from visual effects. Acta Radiol Diagn. 1966;4:463–476
- . Psychophysical RMS granularity for the evaluation of radiographic mottle. J Photogr Sci. 1995;43:103–107
- . Evaluation of radiographic mottle using a single frequency value of the psychophysical Wiener spectrum. J Photogr Sci. 1996;44:89–92
- . Psychophysical evaluation of calibration curve for diagnostic LCD monitor. Radiat Med. 2006;24:653–658
- . Optimum tube voltage for chest radiographs obtained by psychophysical analysis. Med Phys. 1998;25:2170–2175
- . Modulation transfer function of screen-film systems. International Commission on Radiation Units and Measurements; 1986;
- . Basic imaging properties of radiographic systems. Progress in medical radiation physics. Plenum Publishing Corporation. 1985;2:188–189
- . Information spectra for radiographs modified by scatter. Phys Med Biol. 1987;32:667–673
- . Equivalent spatial frequency and optimum film densities for the perceptibility of radiographic contrast of step-edge images. J Phogr Sci. 1995;43:99–102
- . Effects of x-ray tube voltage ripple and current mode on patient dose. Med Phys. 1993;20:1023–1028
- . Computation of bremsstrahlung x-ray spectra and comparison with measured Ge(Li) detector. Phys Med Biol. 1979;24:505–517
- . Emission of characteristic L and K radiation from thick tungsten targets. J Appl Phys. 1972;43:2790–2796
- . Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest. Washington, DC: Technology Administration. USGPO; 1995;
- . Evaluation of cassette performance: physical factors affecting patient exposure and image contrast. Radiology. 1983;146:801–806
- . Balance of required dose and image quality in digital radiography. Radiologe. 2008;48:249–257
PII: S1120-1797(10)00004-9
doi: 10.1016/j.ejmp.2010.01.002
© 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Inc. All rights reserved.