Physica Medica: European Journal of Medical Physics
Volume 27, Issue 1
, Pages 30-38
, January 2011
Generalized EPID calibration for in vivo transit dosimetry
References
- In vivo portal dosimetry by an ionization chamber. Phys Med. 2005;XXI(4):143–152
- Breast in vivo dosimetry by a portal ionization chamber. Med Phys. 2007;34:1121–1127
- . First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose. Radiother Oncol. 1998;47:303–312
- . Transit dosimetry with an electronic portal imaging (EPID) for 115 prostate cancer patients. Int J Radiat Oncol Biol Phys. 1999;45:1297–1303
- In vivo dosimetry by an aSi-based EPID. Med Phys. 2006;33:4414–4422
- Application of a practical method for the isocenter point in vivo dosimetry by a transit signal. Phys Med Biol. 2007;52:5101–5117
- . Routine individualised patient dosimetry using electronic portal imaging devices. Radiother Oncol. 2007;83:65–75
- . A literature review of electronic portal imaging for radiotherapy dosimetry. Radiother Oncol. 2008;88:289–309
- . Assessment of dosimetrical performance in 11 Varian a-Si-500 electronic portal imaging devices. Phys Med Biol. 2008;53:6893–6909
- Dynamic conformal arc therapy: transmitted signal in vivo dosimetry. Med Phys. 2008;35:1830–1839
- Real time dosimetry reconstruction for the breath hold radiotherapy technique: an initial experience. Acta Oncol. 2008;47:1414–1421
- Integration between in vivo dosimetry and image guided radiotherapy for lung tumors. Med Phys. 2009;36(6):2206–2214
- Absorbed dose in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water. IAEA TRS 398 IAEA (International Atomic Energy Agency); 2004;
- Central axis depth dose data for use in radiotherapy. BJR. vol. 25. British Institute of Radiology; 1996;
- . The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields. Radiother Oncol. 2004;71:223–234
- . Monte Carlo computation of dosimetric amorphous silicon electronic portal images. Med Phys. 2004;31:2135–2146
- . A performance comparison of direct and indirect detection flat-panel imagers. Nucl Instrum Meth Phys Res A. 2002;484:351–363
- . A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager. Med Phys. 1999;26:1624–1641
- . PTW-diamond detector: dose rate and particle type dependence. Med Phys. 2000;27(11):2589–2593
- . The calibration of CT Hounsfield units for radiotherapy treatment planning. Phys Med Biol. 1996;41:111–124
- . Automation of radiation treatment planning. IV. Brit J Radiol. 1964;37:544–550
- Relative dosimetry using active matrix flat-panel imager (AMFPI) technology. Med Phys. 1999;261:530–541
- . The Swedish radiation protection institute's regulations on radiation therapy. SSTFS Swedish Radiation Protection Authority; 2000;p. 4
- . State of the art of in vivo dosimetry. Radiat Prot Dosim. 2008;131:117–122
- ISTISAN 99/6 (Istituto Superiore di Sanità (ISS)) Controlli di qualità essenziali in radioterapia con fasci esterni. Italian Guidelines Report; 1999.
- ESTRO. Practical Guidelines for the Implementation of in vivo Dosimetry with Diodes in External Radiotherapy with Photon Beams (Entrance Dose). ESTRO Phys for Clin Radiother Booklet No. 5 (2001).
PII: S1120-1797(10)00010-4
doi: 10.1016/j.ejmp.2010.02.002
© 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Inc. All rights reserved.