The impact of overscan on patient dose with first generation multislice CT scanners

Medical Physics Department, Agios Savvas Hospital, 171 Alexandras Avenue, 115 22 Athens, Greece

Received 5 December 2009; received in revised form 8 February 2010; accepted 7 March 2010. published online 26 April 2010.

Abstract 

Helical scanning requires the irradiation of larger lengths than those planned. This is referred to as overscan and results to an increase of patient dose. Its impact on patient dose was investigated for three first generation multislice CT scanners; a six-, a quad- and a dual-slice. The amount of overscan was determined using the scanners’ dose-length product (DLP) indications and films positioned on the CT table. With the preset protocol for the chest examination selected in all CT scanners, the overscan length calculated from the DLP indications was 6.3, 3.5 and 2cm respectively, whereas the corresponding figures derived from the films were 6.6, 4.8 and 2.5 to 3.2cm. For a 30cm scan length, the respective contributions of overscan to the DLP values were 17, 10 and 6%, whereas for a scan length of 20cm the respective values increased to 24, 15 and 9%. For the smallest scan lengths allowed in helical mode, the respective contributions reached 53, 88 and 67% because for the six-slice scanner the smallest scan length was limited to twice the collimation, whereas in the quad and dual scanners no limitation existed. For small scan lengths the presence of overscan cancels out any dose reduction offered by helical scanning with pitch factor values larger than one and therefore the axial mode should be preferred, when this is not prohibited by the diagnostic task in question.

Keywords: CT, DLP, Overscan, Over-ranging

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1120-1797(10)00021-9

doi:10.1016/j.ejmp.2010.03.001

Physica Medica: European Journal of Medical Physics
Volume 27, Issue 2 , Pages 69-74, April 2011