A liquid-filled ionization chamber for high precision relative dosimetry

  • D.M. González-Castaño

      Affiliations

    • Grupo de Investigación en Radiofísica, Departamento de Física de Partículas, Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
    • Corresponding Author InformationCorresponding author.
  • ,
  • F. Gómez

      Affiliations

    • Grupo de Investigación en Radiofísica, Departamento de Física de Partículas, Universidade de Santiago de Compostela, 15782 Santiago de Compostela, Spain
  • ,
  • L. Brualla

      Affiliations

    • Servicio de Radiofísica, ERESA, Hospital Universitario de Valencia, Spain
  • ,
  • J.V. Roselló

      Affiliations

    • Servicio de Radiofísica, ERESA, Hospital Universitario de Valencia, Spain
  • ,
  • D. Planes

      Affiliations

    • Servicio de Radiofísica, ERESA, Hospital de Elche, Spain
  • ,
  • M. Sánchez

      Affiliations

    • Servicio de Radiofísica, Complexo Hospitalario Universitario de Santiago de Compostela, Spain
  • ,
  • M. Pombar

      Affiliations

    • Servicio de Radiofísica, Complexo Hospitalario Universitario de Santiago de Compostela, Spain

Received 25 May 2009 ,Revised 31 March 2010 ,Accepted 28 April 2010.

References 

  1. Alfonso R, Andreo P, Capote R, Saiful Huq M, Kilby W, Kjäll P, et al. A new formalism for reference dosimetry of small and nonstandard fields. Med Phys. 2008;35(11):5179–5186
  2. Das IJ, Ding GX, Ahnesjö A. Small fields: nonequilibrium radiation dosimetry. Med Phys. 2008;35(1):206–215
  3. Griessbach I, Lapp M, Bohsung J, Gademann G, Harder D. Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams. Med Phys. 2005;32(12):3750–3754
  4. Cheng CW, Cho SH, Taylor M, Das IJ. Determination of zero field size percent depth doses and tissue maximum ratios for stereotactic radiosurgery and IMRT dosimetry: comparison between experimental measurements and Monte Carlo simulation. Med Phys. 2007;34:3149–3157
  5. McKerracher C, Thwaites DI. Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition. Phys Med Biol. 1999;44:2143–2160
  6. Sánchez-Doblado F, Hartmann GH, Pena J, Roselló JV, Russiello G, González-Castaño DM. A new method for output factor determination in MLC shaped narrow beams. Phys Med. 2007;23:58–66
  7. Rustgi SN. Evaluation of the dosimetric characteristics of a diamond detector for photon beam measurements. Med Phys. 1995;22:567–570
  8. Laub WU, Kaulich TW, Nuesslin F. Energy and dose rate dependence of a diamond detector in the dosimetry of 4–25 MV photon beams. Med Phys. 1997;24:535–536
  9. Wickman G. A liquid ionization chamber with high spatial resolution. Phys Med Biol. 1974;19:37–48
  10. Stewart KJ, Elliott A, Seuntjens JP. Development of a guarded liquid ionization chamber for clinical dosimetry. Phys Med Biol. 2007;52:3089–3104
  11. Franco L, Gomez F, Iglesias A, Pardo J, Pazos A, Pena J, et al. Liquid-filled ionization chamber temperature dependence. Nucl Instrum Methods Phys Res A. 2006;560:584–588
  12. Pardo J, Franco L, Gómez F, Iglesias A, Lobato R, Mosquera J, et al. Free ion yield observed in liquid isooctane irradiated by γ rays. Comparison with the Onsager theory. Phys Med Biol. 2004;49:1905–1914
  13. Wickman G, Nyström H. The use of liquids in ionization chambers for high precision radiotherapy dosimetry. Phys Med Biol. 1992;37:1789–1812
  14. Eberle K, Engler J, Hartmann G, Hofmann R, Hörandel JR. First tests of a liquid filled ionization chamber to monitor intensity modulated radiation beams. Phys Med Biol. 2003;48:3555–3564
  15. Pardo J, Franco L, Gómez F, Iglesias A, Pazos A, Pena J, et al. Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance. Phys Med Biol. 2005;50:1703–1716
  16. Pardo J, Roselló JV, Sánchez-Doblado FJ, Gómez F. Verification of intensity modulated profiles using a pixel segmented liquid-filled linear array. Phys Med Biol. 2006;51:N211–N219
  17. Johansson B, Wickman G. General collection efficiency for liquid isooctane and tetramethylsilane used as sensitive media in a parallel-plate ionization chamber. Phys Med Biol. 1997;42:133–145
  18. Dasu A, Löfroth P-O, Wickman G. Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams. Phys Med Biol. 1998;43:21–36

PII: S1120-1797(10)00026-8