« Previous
Next »
Physica Medica: European Journal of Medical Physics
Volume 27, Issue 3
, Pages 135-143
, July 2011
Assessment of computerized treatment planning system accuracy in calculating wedge factors of physical wedged fields for 6 MV photon beams
References
- . Determination of transfer functions of MCP-200 alloy using 6 MV photon beam for beam intensity modulation. J Mechanics Med Biol. 2004;4(3):305–310
- . Spectroscopy of gadolinium ion and disadvantages of gadolinium impurity in tissue compensators and collimators, used in radiation treatment planning. Spectroscopy. 2007;21(4):205–210
- . Compensation in three-dimentional non-coplanar treatment planning. Int J Radiat Oncol Biol Phys. 2002;20(3):215–220
- . A Monte Carlo study of IMRT beamlets in inhomogeneous media. Med Phy. 2003;30(3):296–300
- . Comparison of dosimetric characteristics of Siemens vitual and physical wedges. Med Phy. Oct. 2000;27(10):2267–2277
- . A depth dependence determination of the wedge transmission factor for 4–10 MV photon beams. Med Phys. Jul/Aug 1988;15(4):621–623
- . Field size dependence of wedge factors. Med Phys. Jul/Aug 1988;15(4):624–626
- . Beam characteristics of upper and lower physical wedge systems of Varian accelerators. Phys Med Biol. 2003;48:3667–3683
- . Determination of field size-dependent wedge factors from a few selected measurements. J Appl Clin Med Phys. 2005;6(1):51–60winter
- . The variation in output of symmetric, asymmetric and irregularly shaped wedged radiotherapy fields. Phys Med Biol. 1996;41:2155–2172
- . Wedge factor constituents of high energy photon beams: field size and depth dependence. Radiother Oncol. 1994;30:66–73
- . Wedge factor dependence on depth and field size for various beam energies using symmetric and half-collimated asymmetric jaw settings. Med Phys. Nov/Dec 1992;19(6):1445–1450
- . Studying wedge factors and beam profiles for physical and enhanced dynamic wedges. J Med Phys. 2010;35(1):33–41
- . Wedge factor dependence with depth, field size, and nominal distance-A general computational rule. Med Phy. April 1999;26(4):541–549
- . Measurements of basic parameters in wedged high-energy photon beams using a mini-phantom. Phys Med Biol. 1997;42:1821–1831
- . Characterizing output for the varian enhanced dynamic wedge field. Med Phys. 1998;25:64–70
- . Wedge factor constituents of high-energy photon beams: head and phantom scatter dose components. Radiother Oncol. 1994;32:73–83
- . Technical note: accuracy checks of physical beam modifier factors algorithm used in computerized treatment planning system for a 15 MV photon beam. Rep Pract Oncol Radiother. 2009;14:214–220
- Clinical use of a commercial Monte Carlo treatment planning system for electron beams. Phys Med Biol. 2005;50:1029–1034
- . THERAPLAN plus User Manual. 18th ed.. Canada: MDS Nordion; March 2000;
- . THERAPLAN plus Technical reference Manual. 18th ed.. Canada: MDS Nordion; March 2000;
- Radiation characteristics of helical tomotherapy. Med Phys. February 2004;31(2):396–404
- . Monte Carlo simulations of the differential beam hardening effect of a flattening filter on a therapeutic x-ray beam. Med Phys. 1997;24:1485–1489
- . Linear accelerator photon beam quality at off-axis points. Med Phys. February 1997;24(2):233–239
- Sun J, Doswell G, Cunningham J. Modeling off-axis beam-softening to improve 3D dose-calculation accuracy for wedged photon beams. In: Proceedings of the 22nd Annual EMBS International Conference. Chicago IL, July 2000: p. 23–28.
- . A generic off-axis energy correction for linac photon beam dosimeter. Med Phys. May 1998;25(5):662–667
- . Coplanar beam orientation in radiotherapy: a geometrical approach. Phys Med Biol. 1998;43:2179–2193
PII: S1120-1797(10)00041-4
doi: 10.1016/j.ejmp.2010.06.003
© 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Physica Medica: European Journal of Medical Physics
Volume 27, Issue 3
, Pages 135-143
, July 2011
